{"title":"Crystal Right","description":"","products":[{"product_id":"simplex_cr100_255_1_cuft","title":"10\" x 44\" CR100 Crystal Right Simplex, Autotrol 255 Digital Metered Controller, 1.5 m³\/hr","description":"\u003cp\u003e\u003cspan\u003eCrystal Right™ utilizes an ion exchange process for the elimination of iron, manganese, and hardness present in the water, and its minimum pH requirement is 6.0. It is most efficient with clear water, and ammonia, lead, hydrogen sulphide, and copper can also be reduced. The media bed can be sanitized with chlorine periodically, and the regeneration process is just like a water softener and requires regeneration with the use of salt (sodium chloride). \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCR100 is used where the pH is between 6 and 7 and will increase the pH.\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Crystal Right has a number of advantages over conventional systems in that pH correction, iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003eCombination of Manganese \u0026amp; Iron: Up to 15 PPM\u003cbr\u003eHydrogen Sulfide (H2S): Less than 0.5 PPM\u003cbr\u003eHardness as CaCo3: \u0026gt;50 ppm minimum needed\u003cbr\u003eMinimum TDS: 80 PPM\u003cbr\u003eNo aluminium should be present in feed water.\u003cbr\u003epH Range: 6-11\u003cbr\u003eIron must be in soluble ferrous form*\u003cbr\u003e\u003cbr\u003e*Water containing ferrous iron is clear and colourless because the iron is completely dissolved.\u003cbr\u003e\u003cbr\u003eCrystal Right is an ideal choice for applications where iron, manganese, and hardness require treatment, or where pH needs to be increased without installing an additional system, or when high backwashing rates can't be achieved, as are necessary with Filox or Birm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e21.5Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985567072308,"sku":"","price":655.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_5f5ac46f-9bbf-4f5c-aa4a-3738d02a9bf2.png?v=1671527042"},{"product_id":"simplex_cr100_255_1-5_cuft","title":"10\" x 54\" CR100 Crystal Right Simplex, Autotrol 255 Digital Metered Controller, 1.5 m³\/hr","description":"\u003cp\u003e\u003cspan\u003eCrystal Right™ utilizes an ion exchange process for the elimination of iron, manganese, and hardness present in the water, and its minimum pH requirement is 6.0. It is most efficient with clear water, and ammonia, lead, hydrogen sulphide, and copper can also be reduced. The media bed can be sanitized with chlorine periodically, and the regeneration process is just like a water softener and requires regeneration with the use of salt (sodium chloride). \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCR100 is used where the pH is between 6 and 7 and will increase the pH.\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Crystal Right has a number of advantages over conventional systems in that pH correction, iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003eCombination of Manganese \u0026amp; Iron: Up to 15 PPM\u003cbr\u003eHydrogen Sulfide (H2S): Less than 0.5 PPM\u003cbr\u003eHardness as CaCo3: \u0026gt;50 ppm minimum needed\u003cbr\u003eMinimum TDS: 80 PPM\u003cbr\u003eNo aluminium should be present in feed water.\u003cbr\u003epH Range: 6-11\u003cbr\u003eIron must be in soluble ferrous form*\u003cbr\u003e\u003cbr\u003e*Water containing ferrous iron is clear and colourless because the iron is completely dissolved.\u003cbr\u003e\u003cbr\u003eCrystal Right is an ideal choice for applications where iron, manganese, and hardness require treatment, or where pH needs to be increased without installing an additional system, or when high backwashing rates can't be achieved, as are necessary with Filox or Birm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e21.5Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985567236148,"sku":"","price":899.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_f7d8230c-0c88-401d-961b-141a36073aa5.png?v=1671527044"},{"product_id":"simplex_cr100_268_2_cuft","title":"268, 2 cuft, 1.8m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985567465524,"sku":null,"price":950.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_6f75f929-6c62-41a8-9a86-0d0b3ddae6e9.png?v=1671527045"},{"product_id":"simplex_cr100_268_2-5_cuft","title":"268, 2.5 cuft, 2m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985567694900,"sku":null,"price":1050.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_7769dd27-7260-4396-85b6-8cfd007043de.png?v=1671527047"},{"product_id":"simplex_cr100_268_3-5_cuft","title":"268, 3.5 cuft, 2.5m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985568284724,"sku":null,"price":1400.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_37e42dee-3953-44f3-85ab-726baf1eb325.png?v=1671527048"},{"product_id":"simplex_cr100_278_5_cuft","title":"278, 5 cuft, 3m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985568514100,"sku":null,"price":1750.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_74221aa4-a7ca-421b-a7d7-5fd6012831a4.png?v=1671527049"},{"product_id":"simplex_cr100_278_6_cuft","title":"278, 6 cuft, 4m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985568874548,"sku":null,"price":2100.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_ed7643f4-64f9-4c1c-a3ef-ea0232f61fea.png?v=1671527051"},{"product_id":"simplex_cr100_ws1_ci_1_cuft","title":"WS1 CI, 1 Cuft, 1.5m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985569136692,"sku":null,"price":680.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_6e92d1cf-c617-4688-91fc-4649ce17df25.png?v=1671527053"},{"product_id":"simplex_cr100_ws1_ci_1-5_cuft","title":"WS1 CI, 1.5 Cuft, 1.5m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985569595444,"sku":null,"price":850.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_9adbaa46-a5d3-4b4b-9cf5-8f283e6f26e8.png?v=1671527054"},{"product_id":"simplex_cr100_ws1_ci_2_cuft","title":"WS1 CI, 2 Cuft, 1.8m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985569824820,"sku":null,"price":990.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_41fa0d16-8dad-4b88-9795-1df540d17aba.png?v=1671527055"},{"product_id":"simplex_cr100_ws1_ci_2-5_cuft","title":"WS1 CI, 2.5 Cuft, 2m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985569923124,"sku":null,"price":1050.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_384c1dc2-8cbe-4a0b-aa13-979fbf41f273.png?v=1671527057"},{"product_id":"simplex_cr100_ws1_ci_3-5_cuft","title":"WS1 CI, 3.5 Cuft, 2.5m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985570283572,"sku":null,"price":1400.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_b8b6d04b-e28f-4f4f-bc24-b38ba132860b.png?v=1671527058"},{"product_id":"simplex_cr100_ws1_ci_5_cuft","title":"WS1 CI, 5 Cuft, 3m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985570578484,"sku":null,"price":1850.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_ec4a912c-7ee4-4a40-81e3-d28e32474215.png?v=1671527059"},{"product_id":"simplex_cr100_ws1_ci_6_cuft","title":"WS1 CI, 6 Cuft, 4m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985570676788,"sku":null,"price":1815.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_a7f6ef27-0e2c-493a-8fa8-84b2e871cdf4.png?v=1671527061"},{"product_id":"simplex_cr100_ws2_ci_7_cuft","title":"WS2 CI, 7 Cuft, 5.5m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e7 Cuft\u003c\/td\u003e\n\u003ctd\u003e21x60\u003c\/td\u003e\n\u003ctd\u003e5.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e24Kg\u003c\/td\u003e\n\u003ctd\u003e59m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e11 Cuft\u003c\/td\u003e\n\u003ctd\u003e24x69\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e37Kg\u003c\/td\u003e\n\u003ctd\u003e93m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e19 Cuft\u003c\/td\u003e\n\u003ctd\u003e30x72\u003c\/td\u003e\n\u003ctd\u003e11m³\/hr\u003c\/td\u003e\n\u003ctd\u003e8.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e65Kg\u003c\/td\u003e\n\u003ctd\u003e161m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e27 Cuft\u003c\/td\u003e\n\u003ctd\u003e36x72\u003c\/td\u003e\n\u003ctd\u003e15m³\/hr\u003c\/td\u003e\n\u003ctd\u003e13m³\/hr\u003c\/td\u003e\n\u003ctd\u003e82Kg\u003c\/td\u003e\n\u003ctd\u003e203m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985570906164,"sku":null,"price":3910.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_87cc0281-9b4b-434c-a71a-faf9157b826c.png?v=1671527063"},{"product_id":"simplex_cr100_ws2_ci_11_cuft","title":"WS2 CI, 11 Cuft, 7m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e7 Cuft\u003c\/td\u003e\n\u003ctd\u003e21x60\u003c\/td\u003e\n\u003ctd\u003e5.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e24Kg\u003c\/td\u003e\n\u003ctd\u003e59m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e11 Cuft\u003c\/td\u003e\n\u003ctd\u003e24x69\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e37Kg\u003c\/td\u003e\n\u003ctd\u003e93m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e19 Cuft\u003c\/td\u003e\n\u003ctd\u003e30x72\u003c\/td\u003e\n\u003ctd\u003e11m³\/hr\u003c\/td\u003e\n\u003ctd\u003e8.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e65Kg\u003c\/td\u003e\n\u003ctd\u003e161m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e27 Cuft\u003c\/td\u003e\n\u003ctd\u003e36x72\u003c\/td\u003e\n\u003ctd\u003e15m³\/hr\u003c\/td\u003e\n\u003ctd\u003e13m³\/hr\u003c\/td\u003e\n\u003ctd\u003e82Kg\u003c\/td\u003e\n\u003ctd\u003e203m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985571201076,"sku":null,"price":4920.27,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_8be3af19-26b7-4e3c-a866-158500a2ea07.png?v=1671527066"},{"product_id":"simplex_cr100_ws2_ci_19_cuft","title":"WS2 CI, 19 Cuft, 11m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e7 Cuft\u003c\/td\u003e\n\u003ctd\u003e21x60\u003c\/td\u003e\n\u003ctd\u003e5.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e24Kg\u003c\/td\u003e\n\u003ctd\u003e59m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e11 Cuft\u003c\/td\u003e\n\u003ctd\u003e24x69\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e37Kg\u003c\/td\u003e\n\u003ctd\u003e93m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e19 Cuft\u003c\/td\u003e\n\u003ctd\u003e30x72\u003c\/td\u003e\n\u003ctd\u003e11m³\/hr\u003c\/td\u003e\n\u003ctd\u003e8.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e65Kg\u003c\/td\u003e\n\u003ctd\u003e161m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e27 Cuft\u003c\/td\u003e\n\u003ctd\u003e36x72\u003c\/td\u003e\n\u003ctd\u003e15m³\/hr\u003c\/td\u003e\n\u003ctd\u003e13m³\/hr\u003c\/td\u003e\n\u003ctd\u003e82Kg\u003c\/td\u003e\n\u003ctd\u003e203m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985571430452,"sku":null,"price":6869.32,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_78982866-88d9-4e0f-84bb-2b88ed5f83f0.png?v=1671527069"},{"product_id":"simplex_cr100_ws2_ci_24_cuft","title":"WS2 CI, 24 Cuft, 15m³\/hr, Simplex CR100","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e7 Cuft\u003c\/td\u003e\n\u003ctd\u003e21x60\u003c\/td\u003e\n\u003ctd\u003e5.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e24Kg\u003c\/td\u003e\n\u003ctd\u003e59m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e11 Cuft\u003c\/td\u003e\n\u003ctd\u003e24x69\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e37Kg\u003c\/td\u003e\n\u003ctd\u003e93m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e19 Cuft\u003c\/td\u003e\n\u003ctd\u003e30x72\u003c\/td\u003e\n\u003ctd\u003e11m³\/hr\u003c\/td\u003e\n\u003ctd\u003e8.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e65Kg\u003c\/td\u003e\n\u003ctd\u003e161m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e24 Cuft\u003c\/td\u003e\n\u003ctd\u003e36x72\u003c\/td\u003e\n\u003ctd\u003e15m³\/hr\u003c\/td\u003e\n\u003ctd\u003e13m³\/hr\u003c\/td\u003e\n\u003ctd\u003e82Kg\u003c\/td\u003e\n\u003ctd\u003e203m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985571659828,"sku":null,"price":7827.22,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_34234f7c-ec9f-4d08-a04f-1f55edeba61a.png?v=1671527072"},{"product_id":"simplex_cr200_255_1_cuft","title":"10\" x 44\" CR200 Crystal Right Simplex, Autotrol 255 Digital Metered Controller, 1.5 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron and manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time. The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985572085812,"sku":null,"price":815.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_397a6f79-ee0f-4a2f-aa19-e43894d2c079.png?v=1671527074"},{"product_id":"simplex_cr200_255_1-5_cuft","title":"10\" x 54\" CR200 Crystal Right Simplex, Autotrol 255 Digital Metered Controller, 1.5 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron and manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985572315188,"sku":null,"price":935.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_6f4f1517-f668-4cd8-9651-cbbb30a9ea1e.png?v=1671527076"},{"product_id":"simplex_cr200_268_2_cuft","title":"12\" x 52\" CR200 Crystal Right Simplex, Autotrol 268 Digital Metered Controller, 1.8 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985572479028,"sku":null,"price":1180.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_1bd24735-9c48-44f8-bd97-e9b45bd66220.png?v=1671527077"},{"product_id":"simplex_cr200_268_2-5_cuft","title":"13\" x 54\" CR200 Crystal Right Simplex, Autotrol 268 Digital Metered Controller, 2 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985572741172,"sku":null,"price":1140.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_30e066b0-e3dc-4940-86bc-ca03fc4471ef.png?v=1671527078"},{"product_id":"simplex_cr200_268_3-5_cuft","title":"14\" x 65\" CR200 Crystal Right Simplex, Autotrol 268 Digital Metered Controller, 2.5 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985573101620,"sku":null,"price":1455.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_6518ffc6-f37e-4131-b79a-d70c4cfb506f.png?v=1671527080"},{"product_id":"simplex_cr200_278_5_cuft","title":"16\" x 65\" CR200 Crystal Right Simplex, Autotrol 278 Digital Metered Controller, 3 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985573265460,"sku":null,"price":1770.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_c05d6428-483a-46bf-bb81-597be6493171.png?v=1671527081"},{"product_id":"simplex_cr200_278_6_cuft","title":"18\" x 65\" CR200 Crystal Right Simplex, Autotrol 278 Digital Metered Controller, 4 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 268\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985573462068,"sku":null,"price":2500.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_4f6122ae-8ec5-4bd2-b652-09dc771b0d45.png?v=1671527083"},{"product_id":"simplex_cr200_ws1_ci_1_cuft","title":"10\" x 44\" CR200 Crystal Right Simplex, Clack WS1 CI Digital Metered Controller , 1.5 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 44\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9 kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e12 x 52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7 kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e13 x 54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e137m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e14 x 64\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e16 x 65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003ctd\u003e50.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e18 x 65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003ctd\u003e67.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985573789748,"sku":null,"price":820.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_9130881b-4a9c-4831-a058-99d679ca1708.png?v=1671527084"},{"product_id":"simplex_cr200_ws1_ci_1-5_cuft","title":"10\" x 54\" CR200 Crystal Right Simplex, Clack WS1 CI Digital Metered Controller, 1.5 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 44\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9 kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e12 x 52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7 kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e13 x 54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e137m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e14 x 64\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e16 x 65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003ctd\u003e50.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e18 x 65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003ctd\u003e67.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985574019124,"sku":null,"price":865.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_601e811c-9ebe-4572-b9e4-0faa9e845a6f.png?v=1671527086"},{"product_id":"simplex_cr200_ws1_ci_2_cuft","title":"12\" x 52\" CR200 Crystal Right Simplex, Clack WS1 CI Digital Metered Controller, 1.8 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 44\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9 kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e12 x 52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7 kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e13 x 54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e137m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e14 x 64\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e16 x 65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003ctd\u003e50.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e18 x 65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003ctd\u003e67.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985574150196,"sku":null,"price":1000.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_52efe30d-9f75-4d8b-b174-1d247226e0dc.png?v=1671527087"},{"product_id":"simplex_cr200_ws1_ci_2-5_cuft","title":"13\" x 54\" CR200 Crystal Right Simplex, Clack WS1 CI Digital Metered Controller, 2 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 44\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9 kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e12 x 52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7 kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e13 x 54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e137m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e14 x 64\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e16 x 65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003ctd\u003e50.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e18 x 65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003ctd\u003e67.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985574608948,"sku":"","price":1250.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_3d65d538-28be-4556-a234-d164624cbac7.png?v=1671527089"},{"product_id":"simplex_cr200_ws1_ci_3-5_cuft","title":"14\" x 65\" CR200 Crystal Right Simplex, Clack WS1 CI Digital Metered Controller, 2.5 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 44\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9 kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e12 x 52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7 kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e13 x 54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e137m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e14 x 64\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e16 x 65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003ctd\u003e50.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e18 x 65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003ctd\u003e67.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985574838324,"sku":null,"price":1600.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_639c2fa4-d72f-4162-a83f-aad4c528c5a1.png?v=1671527090"},{"product_id":"simplex_cr200_ws1_ci_5_cuft","title":"16\" x 65\" CR200 Crystal Right Simplex, Clack WS1 CI Digital Metered Controller, 3 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 44\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9 kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e12 x 52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7 kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e13 x 54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e137m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e14 x 64\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e16 x 65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003ctd\u003e50.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e18 x 65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003ctd\u003e67.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985575198772,"sku":null,"price":1900.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_adaedf33-adc7-4c93-8336-db200d4d133b.png?v=1671527092"},{"product_id":"simplex_cr200_ws1_ci_6_cuft","title":"18\" x 65\" CR200 Crystal Right Simplex, Clack WS1 CI Digital Metered Controller, 4 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 44\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9 kg\u003c\/td\u003e\n\u003ctd\u003e12.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e10 x 54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003ctd\u003e20.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e12 x 52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7 kg\u003c\/td\u003e\n\u003ctd\u003e26m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e13 x 54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e137m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9 kg\u003c\/td\u003e\n\u003ctd\u003e31.2m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e14 x 64\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12 kg\u003c\/td\u003e\n\u003ctd\u003e39.5m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e16 x 65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15 kg\u003c\/td\u003e\n\u003ctd\u003e50.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS1 CI\u003c\/td\u003e\n\u003ctd\u003e18 x 65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\u003ctd\u003e67.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985575428148,"sku":null,"price":2500.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_ba6b2d7d-1965-4426-9a85-14814d627f3d.png?v=1671527093"},{"product_id":"simplex_cr200_ws2_ci_7_cuft","title":"21\" x 60\" CR200 Crystal Right Simplex, Clack WS2 CI Digital Metered Controller, 5.5 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e21 x 60\u003c\/td\u003e\n\u003ctd\u003e7 Cuft\u003c\/td\u003e\n\u003ctd\u003e5.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e4.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e24 kg\u003c\/td\u003e\n\u003ctd\u003e79m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e24 x 69\u003c\/td\u003e\n\u003ctd\u003e11 Cuft\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e37 kg\u003c\/td\u003e\n\u003ctd\u003e124m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e30 x 72\u003c\/td\u003e\n\u003ctd\u003e19 Cuft\u003c\/td\u003e\n\u003ctd\u003e11m³\/hr\u003c\/td\u003e\n\u003ctd\u003e8.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e65 kg\u003c\/td\u003e\n\u003ctd\u003e214m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e36 x 72\u003c\/td\u003e\n\u003ctd\u003e24 Cuft\u003c\/td\u003e\n\u003ctd\u003e15m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9.6m³\/hr\u003c\/td\u003e\n\u003ctd\u003e82 kg\u003c\/td\u003e\n\u003ctd\u003e293m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985575657524,"sku":null,"price":4500.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_2201168f-ad4f-4686-8380-bdde186503d5.png?v=1671527095"},{"product_id":"simplex_cr200_ws2_ci_11_cuft","title":"24\" x 69\" CR200 Crystal Right Simplex, Clack WS2 CI Digital Metered Controller, 7 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e21 x 60\u003c\/td\u003e\n\u003ctd\u003e7 Cuft\u003c\/td\u003e\n\u003ctd\u003e5.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e4.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e24 kg\u003c\/td\u003e\n\u003ctd\u003e79m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e24 x 69\u003c\/td\u003e\n\u003ctd\u003e11 Cuft\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e37 kg\u003c\/td\u003e\n\u003ctd\u003e124m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e30 x 72\u003c\/td\u003e\n\u003ctd\u003e19 Cuft\u003c\/td\u003e\n\u003ctd\u003e11m³\/hr\u003c\/td\u003e\n\u003ctd\u003e8.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e65 kg\u003c\/td\u003e\n\u003ctd\u003e214m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e36 x 72\u003c\/td\u003e\n\u003ctd\u003e24 Cuft\u003c\/td\u003e\n\u003ctd\u003e15m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9.6m³\/hr\u003c\/td\u003e\n\u003ctd\u003e82 kg\u003c\/td\u003e\n\u003ctd\u003e293m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985576083508,"sku":null,"price":5200.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_a906c94e-df19-41ad-b5fd-9e59ef6d5fc4.png?v=1671527096"},{"product_id":"simplex_cr200_ws2_ci_19_cuft","title":"30\" x 72\" CR200 Crystal Right Simplex, Clack WS2 CI Digital Metered Controller, 11 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e21 x 60\u003c\/td\u003e\n\u003ctd\u003e7 Cuft\u003c\/td\u003e\n\u003ctd\u003e5.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e4.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e24 kg\u003c\/td\u003e\n\u003ctd\u003e79m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e24 x 69\u003c\/td\u003e\n\u003ctd\u003e11 Cuft\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e37 kg\u003c\/td\u003e\n\u003ctd\u003e124m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e30 x 72\u003c\/td\u003e\n\u003ctd\u003e19 Cuft\u003c\/td\u003e\n\u003ctd\u003e11m³\/hr\u003c\/td\u003e\n\u003ctd\u003e8.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e65 kg\u003c\/td\u003e\n\u003ctd\u003e214m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e36 x 72\u003c\/td\u003e\n\u003ctd\u003e24 Cuft\u003c\/td\u003e\n\u003ctd\u003e15m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9.6m³\/hr\u003c\/td\u003e\n\u003ctd\u003e82 kg\u003c\/td\u003e\n\u003ctd\u003e293m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985576378420,"sku":null,"price":7500.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_f4220ee5-52b1-44ff-8682-28556cf7b636.png?v=1671527098"},{"product_id":"simplex_cr200_ws2_ci_24_cuft","title":"36\" x 72\" CR200 Crystal Right Simplex, Clack WS2 CI Digital Metered Controller, 15 m³\/hr","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e21 x 60\u003c\/td\u003e\n\u003ctd\u003e7 Cuft\u003c\/td\u003e\n\u003ctd\u003e5.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e4.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e24 kg\u003c\/td\u003e\n\u003ctd\u003e79m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e24 x 69\u003c\/td\u003e\n\u003ctd\u003e11 Cuft\u003c\/td\u003e\n\u003ctd\u003e7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e37 kg\u003c\/td\u003e\n\u003ctd\u003e124m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e30 x 72\u003c\/td\u003e\n\u003ctd\u003e19 Cuft\u003c\/td\u003e\n\u003ctd\u003e11m³\/hr\u003c\/td\u003e\n\u003ctd\u003e8.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e65 kg\u003c\/td\u003e\n\u003ctd\u003e214m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClack WS2 CI\u003c\/td\u003e\n\u003ctd\u003e36 x 72\u003c\/td\u003e\n\u003ctd\u003e24 Cuft\u003c\/td\u003e\n\u003ctd\u003e15m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9.6m³\/hr\u003c\/td\u003e\n\u003ctd\u003e82 kg\u003c\/td\u003e\n\u003ctd\u003e293m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985576640564,"sku":null,"price":8900.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200.png?v=1671527099"},{"product_id":"evolve_cr100_1-5_cuft","title":"CR100, 1.5 cuft, 1.5m³\/hr, Evolve","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985577099316,"sku":null,"price":1050.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_Evolve_8c9f0a21-54ff-4832-aec1-5f18afbd974d.png?v=1671527101"},{"product_id":"evolve_cr100_2_cuft","title":"CR100, 2 cuft, 1.8m³\/hr, Evolve","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985577459764,"sku":null,"price":1120.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_Evolve_cf3c72cc-5624-47da-912a-c46003bc497d.png?v=1671527103"},{"product_id":"evolve_cr100_2-5_cuft","title":"CR100, 2.5 cuft, 2m³\/hr, Evolve","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985577918516,"sku":null,"price":1400.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_Evolve_254866cd-83dc-447e-ab54-b7641ea5cda3.png?v=1671527104"},{"product_id":"evolve_cr100_3-5_cuft","title":"CR100, 3.5 cuft, 2.5m³\/hr, Evolve","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR100\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985578213428,"sku":null,"price":1800.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_Evolve_708d927d-d446-41ee-9251-bd1e12964795.png?v=1671527106"},{"product_id":"evolve_cr200_1-5_cuft","title":"CR200, 1.5 cuft, 1.5m³\/hr, Evolve","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985578606644,"sku":null,"price":1055.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_Evolve_4b3085d9-0000-4228-a344-8f87eadc657f.png?v=1671527108"},{"product_id":"evolve_cr200_2_cuft","title":"CR200, 2 cuft, 1.8m³\/hr, Evolve","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985579196468,"sku":null,"price":1130.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_Evolve_ae985d86-783b-40cf-9a4c-448aabd7f32c.png?v=1671527109"},{"product_id":"evolve_cr200_2-5_cuft","title":"CR200, 2.5 cuft, 2m³\/hr, Evolve","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985579360308,"sku":null,"price":1450.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_Evolve_cc598dbe-124d-4189-8716-6abc1f344d79.png?v=1671527111"},{"product_id":"evolve_cr200_3-5_cuft","title":"CR200, 3.5 cuft, 2.5m³\/hr, Evolve","description":"\u003cp\u003eCrystal Right™ works by an ion exchange process which removes iron, manganese and hardness. The minimum pH requirement for CR200 is 7.0. CR200 has the highest capacity from removing hardness, iron amd manganese. Crystal Right works at its best on clear water, i.e. when the iron\/manganese are in a dissolved form. Crystal Right will also remove hardness with no extra treatment. Ammonia, lead, hydrogen sulphide and copper can also be reduced. The media bed can be sanitised with chlorine from time to time.The regeneration process is exactly the same as that used in a water softener and requires regeneration with salt (sodium chloride). CR200 is used where the pH is between7 and 11. Crystal Right CR200 has a number of advantages over conventional systems in that iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvolve CR200\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985579589684,"sku":null,"price":1700.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR200_Evolve_92093f57-9a59-4745-adb5-dbe3b6fbd7b1.png?v=1671527112"},{"product_id":"duplex_cr100_255_1_cuft","title":"10\" x 44\" CR100 Crystal Right Duplex, Autotrol 255 Digital Metered Controller, 1.5 m³\/hr","description":"\u003cp\u003e\u003cspan\u003eCrystal Right™ utilizes an ion exchange process for the elimination of iron, manganese, and hardness present in the water, and its minimum pH requirement is 6.0. It is most efficient with clear water, and ammonia, lead, hydrogen sulphide, and copper can also be reduced. The media bed can be sanitized with chlorine periodically, and the regeneration process is just like a water softener and requires regeneration with the use of salt (sodium chloride). \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCR100 is used where the pH is between 6 and 7 and will increase the pH.\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Crystal Right has a number of advantages over conventional systems in that pH correction, iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003eCombination of Manganese \u0026amp; Iron: Up to 15 PPM\u003cbr\u003eHydrogen Sulfide (H2S): Less than 0.5 PPM\u003cbr\u003eHardness as CaCo3: \u0026gt;50 ppm minimum needed\u003cbr\u003eMinimum TDS: 80 PPM\u003cbr\u003eNo aluminium should be present in feed water.\u003cbr\u003epH Range: 6-11\u003cbr\u003eIron must be in soluble ferrous form*\u003cbr\u003e\u003cbr\u003e*Water containing ferrous iron is clear and colourless because the iron is completely dissolved.\u003cbr\u003e\u003cbr\u003eCrystal Right is an ideal choice for applications where iron, manganese, and hardness require treatment, or where pH needs to be increased without installing an additional system, or when high backwashing rates can't be achieved, as are necessary with Filox or Birm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable style=\"width: 554px;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 68px;\" scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth style=\"width: 36px;\" scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth style=\"width: 10px;\" scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth style=\"width: 133px;\" scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth style=\"width: 87px;\" scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth style=\"width: 34px;\" scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth style=\"width: 136px;\" scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68px;\"\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd style=\"width: 36px;\"\u003e10x44\u003c\/td\u003e\n\u003ctd style=\"width: 10px;\"\u003e1 Cuft\u003c\/td\u003e\n\u003ctd style=\"width: 133px;\"\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd style=\"width: 87px;\"\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd style=\"width: 34px;\"\u003e3.9Kg\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68px;\"\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd style=\"width: 36px;\"\u003e10x54\u003c\/td\u003e\n\u003ctd style=\"width: 10px;\"\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd style=\"width: 133px;\"\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd style=\"width: 87px;\"\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd style=\"width: 34px;\"\u003e5Kg\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68px;\"\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd style=\"width: 36px;\"\u003e12x52\u003c\/td\u003e\n\u003ctd style=\"width: 10px;\"\u003e2 Cuft\u003c\/td\u003e\n\u003ctd style=\"width: 133px;\"\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd style=\"width: 87px;\"\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd style=\"width: 34px;\"\u003e6.7Kg\u003c\/td\u003e\n\u003ctd style=\"width: 136px;\"\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985580146740,"sku":"","price":1500.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100.png?v=1671527114"},{"product_id":"duplex_cr100_255_1-5_cuft","title":"10\" x 54\" CR100 Crystal Right Duplex, Autotrol 255 Digital Metered Controller, 1.5 m³\/hr","description":"\u003cp\u003e\u003cspan\u003eCrystal Right™ utilizes an ion exchange process for the elimination of iron, manganese, and hardness present in the water, and its minimum pH requirement is 6.0. It is most efficient with clear water, and ammonia, lead, hydrogen sulphide, and copper can also be reduced. The media bed can be sanitized with chlorine periodically, and the regeneration process is just like a water softener and requires regeneration with the use of salt (sodium chloride). \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCR100 is used where the pH is between 6 and 7 and will increase the pH.\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Crystal Right has a number of advantages over conventional systems in that pH correction, iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003eCombination of Manganese \u0026amp; Iron: Up to 15 PPM\u003cbr\u003eHydrogen Sulfide (H2S): Less than 0.5 PPM\u003cbr\u003eHardness as CaCo3: \u0026gt;50 ppm minimum needed\u003cbr\u003eMinimum TDS: 80 PPM\u003cbr\u003eNo aluminium should be present in feed water.\u003cbr\u003epH Range: 6-11\u003cbr\u003eIron must be in soluble ferrous form*\u003cbr\u003e\u003cbr\u003e*Water containing ferrous iron is clear and colourless because the iron is completely dissolved.\u003cbr\u003e\u003cbr\u003eCrystal Right is an ideal choice for applications where iron, manganese, and hardness require treatment, or where pH needs to be increased without installing an additional system, or when high backwashing rates can't be achieved, as are necessary with Filox or Birm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985580376116,"sku":"","price":1820.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_5e87a0fb-7947-4b4e-b572-bafe4dbcdc99.png?v=1671527115"},{"product_id":"duplex_cr100_255_2_cuft","title":"12\" x 52\" CR100 Crystal Right Duplex, Autotrol 255 Digital Metered Controller, 1.8 m³\/hr","description":"\u003cp\u003e\u003cspan\u003eCrystal Right™ utilizes an ion exchange process for the elimination of iron, manganese, and hardness present in the water, and its minimum pH requirement is 6.0. It is most efficient with clear water, and ammonia, lead, hydrogen sulphide, and copper can also be reduced. The media bed can be sanitized with chlorine periodically, and the regeneration process is just like a water softener and requires regeneration with the use of salt (sodium chloride). \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCR100 is used where the pH is between 6 and 7 and will increase the pH.\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Crystal Right has a number of advantages over conventional systems in that pH correction, iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003eCombination of Manganese \u0026amp; Iron: Up to 15 PPM\u003cbr\u003eHydrogen Sulfide (H2S): Less than 0.5 PPM\u003cbr\u003eHardness as CaCo3: \u0026gt;50 ppm minimum needed\u003cbr\u003eMinimum TDS: 80 PPM\u003cbr\u003eNo aluminium should be present in feed water.\u003cbr\u003epH Range: 6-11\u003cbr\u003eIron must be in soluble ferrous form*\u003cbr\u003e\u003cbr\u003e*Water containing ferrous iron is clear and colourless because the iron is completely dissolved.\u003cbr\u003e\u003cbr\u003eCrystal Right is an ideal choice for applications where iron, manganese, and hardness require treatment, or where pH needs to be increased without installing an additional system, or when high backwashing rates can't be achieved, as are necessary with Filox or Birm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e10x44\u003c\/td\u003e\n\u003ctd\u003e1 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.9Kg\u003c\/td\u003e\n\u003ctd\u003e7.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e10x54\u003c\/td\u003e\n\u003ctd\u003e1.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1m³\/hr\u003c\/td\u003e\n\u003ctd\u003e5Kg\u003c\/td\u003e\n\u003ctd\u003e13.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 255\u003c\/td\u003e\n\u003ctd\u003e12x52\u003c\/td\u003e\n\u003ctd\u003e2 Cuft\u003c\/td\u003e\n\u003ctd\u003e1.8m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e6.7Kg\u003c\/td\u003e\n\u003ctd\u003e17.4m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985580572724,"sku":"","price":2070.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_c36c9ec9-8b84-4fa9-bf91-a862c816ec64.png?v=1671527117"},{"product_id":"duplex_cr100_278_2-5_cuft","title":"13\" x 54\" CR100 Crystal Right Duplex, Autotrol 278 Digital Metered Controller, 2 m³\/hr","description":"\u003cp\u003e\u003cspan\u003eCrystal Right™ utilizes an ion exchange process for the elimination of iron, manganese, and hardness present in the water, and its minimum pH requirement is 6.0. It is most efficient with clear water, and ammonia, lead, hydrogen sulphide, and copper can also be reduced. The media bed can be sanitized with chlorine periodically, and the regeneration process is just like a water softener and requires regeneration with the use of salt (sodium chloride). \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCR100 is used where the pH is between 6 and 7 and will increase the pH.\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Crystal Right has a number of advantages over conventional systems in that pH correction, iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003eCombination of Manganese \u0026amp; Iron: Up to 15 PPM\u003cbr\u003eHydrogen Sulfide (H2S): Less than 0.5 PPM\u003cbr\u003eHardness as CaCo3: \u0026gt;50 ppm minimum needed\u003cbr\u003eMinimum TDS: 80 PPM\u003cbr\u003eNo aluminium should be present in feed water.\u003cbr\u003epH Range: 6-11\u003cbr\u003eIron must be in soluble ferrous form*\u003cbr\u003e\u003cbr\u003e*Water containing ferrous iron is clear and colourless because the iron is completely dissolved.\u003cbr\u003e\u003cbr\u003eCrystal Right is an ideal choice for applications where iron, manganese, and hardness require treatment, or where pH needs to be increased without installing an additional system, or when high backwashing rates can't be achieved, as are necessary with Filox or Birm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985580867636,"sku":"","price":2159.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_be730b15-d93f-467d-8cd5-6413ed5650f5.png?v=1671527119"},{"product_id":"duplex_cr100_278_3-5_cuft","title":"14\" x 65\" CR100 Crystal Right Duplex, Autotrol 278 Digital Metered Controller, 2.5 m³\/hr","description":"\u003cp\u003e\u003cspan\u003eCrystal Right™ utilizes an ion exchange process for the elimination of iron, manganese, and hardness present in the water, and its minimum pH requirement is 6.0. It is most efficient with clear water, and ammonia, lead, hydrogen sulphide, and copper can also be reduced. The media bed can be sanitized with chlorine periodically, and the regeneration process is just like a water softener and requires regeneration with the use of salt (sodium chloride). \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCR100 is used where the pH is between 6 and 7 and will increase the pH.\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Crystal Right has a number of advantages over conventional systems in that pH correction, iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003eCombination of Manganese \u0026amp; Iron: Up to 15 PPM\u003cbr\u003eHydrogen Sulfide (H2S): Less than 0.5 PPM\u003cbr\u003eHardness as CaCo3: \u0026gt;50 ppm minimum needed\u003cbr\u003eMinimum TDS: 80 PPM\u003cbr\u003eNo aluminium should be present in feed water.\u003cbr\u003epH Range: 6-11\u003cbr\u003eIron must be in soluble ferrous form*\u003cbr\u003e\u003cbr\u003e*Water containing ferrous iron is clear and colourless because the iron is completely dissolved.\u003cbr\u003e\u003cbr\u003eCrystal Right is an ideal choice for applications where iron, manganese, and hardness require treatment, or where pH needs to be increased without installing an additional system, or when high backwashing rates can't be achieved, as are necessary with Filox or Birm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985581326388,"sku":"","price":2840.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_ac8392c6-5e35-4eba-82b4-d84edc5a1273.png?v=1671527121"},{"product_id":"duplex_cr100_278_5_cuft","title":"16\" x 65\" CR100 Crystal Right Duplex, Autotrol 278 Digital Metered Controller, 3 m³\/hr","description":"\u003cp\u003e\u003cspan\u003eCrystal Right™ utilizes an ion exchange process for the elimination of iron, manganese, and hardness present in the water, and its minimum pH requirement is 6.0. It is most efficient with clear water, and ammonia, lead, hydrogen sulphide, and copper can also be reduced. The media bed can be sanitized with chlorine periodically, and the regeneration process is just like a water softener and requires regeneration with the use of salt (sodium chloride). \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eCR100 is used where the pH is between 6 and 7 and will increase the pH.\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e Crystal Right has a number of advantages over conventional systems in that pH correction, iron\/manganese removal and softening can all be addressed in a single process and at lower pHs.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRequirements:\u003c\/strong\u003e\u003cbr\u003eCombination of Manganese \u0026amp; Iron: Up to 15 PPM\u003cbr\u003eHydrogen Sulfide (H2S): Less than 0.5 PPM\u003cbr\u003eHardness as CaCo3: \u0026gt;50 ppm minimum needed\u003cbr\u003eMinimum TDS: 80 PPM\u003cbr\u003eNo aluminium should be present in feed water.\u003cbr\u003epH Range: 6-11\u003cbr\u003eIron must be in soluble ferrous form*\u003cbr\u003e\u003cbr\u003e*Water containing ferrous iron is clear and colourless because the iron is completely dissolved.\u003cbr\u003e\u003cbr\u003eCrystal Right is an ideal choice for applications where iron, manganese, and hardness require treatment, or where pH needs to be increased without installing an additional system, or when high backwashing rates can't be achieved, as are necessary with Filox or Birm.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecification\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eValve\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSize\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eVolume\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eMax Service Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eBackwash Flow\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eSalt\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eCapacity @ 100ppm CaCO₃\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e13x54\u003c\/td\u003e\n\u003ctd\u003e2.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.7m³\/hr\u003c\/td\u003e\n\u003ctd\u003e9Kg\u003c\/td\u003e\n\u003ctd\u003e21.8m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e14x65\u003c\/td\u003e\n\u003ctd\u003e3.5 Cuft\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e1.9m³\/hr\u003c\/td\u003e\n\u003ctd\u003e12Kg\u003c\/td\u003e\n\u003ctd\u003e29.7m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e16x65\u003c\/td\u003e\n\u003ctd\u003e5 Cuft\u003c\/td\u003e\n\u003ctd\u003e3m³\/hr\u003c\/td\u003e\n\u003ctd\u003e2.5m³\/hr\u003c\/td\u003e\n\u003ctd\u003e15Kg\u003c\/td\u003e\n\u003ctd\u003e38m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutotrol 278\u003c\/td\u003e\n\u003ctd\u003e18x65\u003c\/td\u003e\n\u003ctd\u003e6 Cuft\u003c\/td\u003e\n\u003ctd\u003e4m³\/hr\u003c\/td\u003e\n\u003ctd\u003e3.2m³\/hr\u003c\/td\u003e\n\u003ctd\u003e20Kg\u003c\/td\u003e\n\u003ctd\u003e51m³\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Kennet Water","offers":[{"title":"Default Title","offer_id":39985581555764,"sku":"","price":3299.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/products\/Prod_CR100_c625b16d-447a-4f3e-ac6d-d1a767646db0.png?v=1671527122"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0579\/7763\/4868\/collections\/Crystal_Right.png?v=1646913893","url":"https:\/\/store.genex.co.uk\/collections\/crystal-right.oembed?page=5","provider":"Genex","version":"1.0","type":"link"}